Estimating maximum temperatures attained during fires in building stoneworks by thermoluminescence : a case study from Uncastillo, Saragossa (Spain

Part of : Mediterranean archaeology & archaeometry : international journal ; Vol.13, No.3, 2013, pages 145-153

Issue:
Pages:
145-153
Author:
Abstract:
Knowing the maximum temperatures attained by stonework during past fires in historical buildings is important to understand the damage caused to the materials and the subsequent weathering history after the fire. Thermoluminescence (TL) provides a tool to assess such temperature but different protocols exist. TL has been tested to assess the maximum temperature reached by a past fire on the surface of calcitic sandstone (frequently used in historical buildings in Saragossa, Central- Eastern Spain). We have prepared subsamples of this sandstone annealed from 200°C to 700°C. Quartz extracts from such samples were used for testing different TL protocols, from measuring the erosion of the whole TL glow curve of quartz extracted to test the Thermal Activation Characteristic (TAC) and other more recent approaches, such as comparing the sensitization of the integrated 110, 200 and 250-400°C peaks at different irradiation doses or a full predose protocol. The erosion of the TL glow curve of quartz seems to underestimate the attained temperature while the other tested protocols indicate that the temperature reached was 400°C
Subject:
Subject (LC):
Keywords:
historical fire, TL, quartz, firing temperature
References (1):
  1. Aitken, M.J. (1985) Thermoluminescence dating. Academic Press, London.Alarcon-Ruiz, A., Platret, G., Massieu, E., Ehrlacher, A. (2005) The use of thermal analysis in assessingthe effect of temperature on a cement paste. Cement and Concrete Research, vol. 35 (3),609-613.Bailey, R.M. (2001) Towards a general kinetic model for optically and thermally stimulated luminescenceof quartz. Radiation Measurements, vol. 33 (1), 17-45.Bailiff, I.K. and Petrov, S.A. (1999) The use of the 210°C TL peak in quartz for retrospective dosimetry.Radiation Protection Dosimetry, vol. 84 (1-4), 551-554.Bøtter-Jensen, L., Agersnap Larsen, N., Mejdahl, V., Poolton, N.R.J., Morris, M.F., McKeever, S.W.S.(1995) Luminescence sensitivity changes in quartz as a result of annealing. Radiation Measurements,vol. 24 (4), 535-541.Chakrabarti, B., Yates, T., Lewry, A. (1996) Effect of fire damage on natural stonework in buildings.Construction and Building Materials, vol. 10 (7), 539-544.Charitidis C, Kitis G, Furetta C, Charalambous S. (2000) Superlinearity of synthetic quartz: Dependenceon the firing temperature. Nuclear Instruments and Methods in Physics Research B, vol.168 (3), 404-410.Chen, R., Yang, X.H., McKeever, S.W.S. (1988) The strongly supralinear dose dependence of thermoluminescencein synthetic quartz. Journal of Physics D: Applied Physics, vol. 21 (9), 1452-1457.Chew, M.Y.L., Millan, P.T., Kelly, J.C. (1987) The Temperature History of Heated Concrete Measuredby Thermoluminescence. Non-Destructive Testing, vol. 24 (5), 116-120.Cioni, P., Croce, P., Salvatore, W. (2001) Assessing fire damage to r.c. elements. Fire Safety Journal,vol. 36 (2), 181-199Felicetti, R. (2011) Assessment Methods of Fire Damages in Concrete Tunnel Linings. Fire Technology,Vol. 47, 2.Fernández-Mosquera D, Sanjurjo-Sánchez J (2008) A simple method to separate quartz and feldsparand its application to TL/OSL methods. Geochronometria, vol. 30, 41-47.Fleming, S.J. (1973) The pre-dose technique: a new thermoluminescent dating method. Archaeometry,vol. 15, 13-30.Franklin, A.D., Prescott, J.R., Scholefield, R.B. (1995) The mechanism of thermoluminescence in anAustralian sedimentary quartz. Journal of Luminescence, vol. 63 (5-6), 317–326.Gartia, R.K. (2009) Paleothermometry of NaCl as evidenced from thermoluminescence data. NuclearInstruments and Methods in Physics Research B, vol. 267 (17), 2903-2907Georgali, B., Tsakiridis, P.E. (2005) Microstructure of fire-damaged concrete. A case study. Cementand Concrete Composites, vol. 27 (2), 255-259.Göksu, H.Y., Wieser, A., Regulla, D.F. (1989) 110oC TL peak records the ancient heat trearment offlint. Ancient TL, vol. 7 (1), 15-17.Gomez-Heras, M., Fort, R. Morcillo, M., Molpeceres, C., Ocaña, J.L., 2008. Laser heating: a minimallyinvasive technique for studying fire-generated heating in building stone. Materiales deConstrucción, vol. 58 (289-290), 203-217.Gomez-Heras, M., McCabe, S., Smith, B.J., Fort, R., (2009). Impacts of Fire on Stone-Built Heritage:an Overview. Journal of Architectural Conservation, vol. 15 (2), 47-58.Hajpal, M., Török, A. (2004) Mineralogical and colour changes of quartz sandstones by heat. EnvironmentalGeology, vol. 46 (3-4), 311-322.Handoo, S.K., Agarwal, S., Agarwal, S.K. (2002) Physicochemical, mineralogical, and morphologicalcharacteristics of concrete exposed to elevated temperatures. Cement and Concrete Research,vol. 32 (7), 1009-1018.Ingham, J.P. (2009) Application of petrographic examination techniques to the assessment of firedamagedconcrete and masonry structures. Materials Characterization, vol. 60 (7), 700-709.Koca, M.Y., Ozden, G., Yavuz, A.B., Kincal, C., Onargan, T., Kucuk, K. (2006) Changes in the engineeringproperties of marble in fire-exposed columns. International Journal of Rock Mechanicsand Mining Sciences, vol. 43 (4), 520-530.Koul, D.K., Nambi, K.S.V., Singhvi, A.K., Bhat, C.L., Gupta, P.K. (1996) Feasibility of Estimating FiringTemperature Using the 110oC TL Peak of Quartz. Applied Radiation and Isotopes, vol. 47(2), 191-194.Koul, D.K (2006) Role of alkali ions in limiting the capacity of the 110oC peak of quartz to rememberthe firing temperature. Applied Radiation and Isotopes, vol. 64 (1), 110-115.Lin, D.F; Wang, H.Y.; Luo, H.L. (2004) Assessment of Fire-Damaged Mortar Using Digital ImageProcess. Journal of Materials in Civil Engineering, vol. 16 (4), 383-386.Liritzis, I. (1982) Non-linear TL response of quartz grains: some annealling experiments. P.A.C.T., I,vol. 6, 209-213.Pei, X., Han, Y., Sun, X. (1997) Determining burn degree of fire-damaged concrete constructions bythermoluminescence. Chinese Science Bulletin, vol. 42 (21), 1829-1833.Placido, F. (1980) Thermoluminescence test for fire-damaged concrete. Magazine of Concrete Research,vol. 32 (111), 112-116.Polymeris GS, Sakalis A, Papadopoulou D, Dallas G, Kitis G, Tsirliganis NC (2007) Firing temperatureof pottery using TL and OSL techniques. Nuclear Instruments and Methods in PhysicsResearch A, vol. 580 (1), 747-750.Poon, C.S., Azhar, S., Anson, M., Wong, Y.L. (2001) Strength and durability recovery of firedamagedconcrete after post-fire-curing. Cement and Concrete Research, vol. 31 (10), 1307–1318Sacadura, J.F. (2005) Radiative heat transfer in fire safety science. Journal of Quantitative Spectroscopyand Radiative Transfer, vol. 93 (1), 5-24.Short, N.R., Purkiss, J.A., Guise, S.E. (2001) Assessment of fire damaged concrete using colour imageanalysis. Construction and Building Materials, vol. 15 (1), 9-15.Sunta CM, David M. (1982) Firing temperature of pottery from pre-dose sensitization of TL. Journalof the Council of Europe PACT, vol. 6, 460-467.Viskanta, R. (2008) Overview of some radiative transfer issues in simulation of unwanted fires. InternationalJournal of Thermal Sciences, vol. 47 (12), 1563-1570.Watson IA, Aitken MJ. (1985) Firing temperature analysis using the 110°C peak of quartz. NuclearTracks and Radiation Measurements, vol. 10 (4-6), 517-520.Zimmerman J. (1971) The radiation induced increase of the 110°C TL sensitivity of fired quartz.Journal of Physics C: Solid State Physics, vol. 4 (18), 3265-3276.